Chat with us, powered by LiveChat Skip to content

Trafag DTP 8180 Display Temperature Transmitter

SKU TR-DTP-8180-211B
by Trafag

Options are based on Process Connection

Trafag offers highly configurable temperature transmitters, based on the unique requirements of the application.

The DTP 8180 is the ideal combination of temperature transmitter, 2 PNP switching outputs, with pressure a display, and of a Class 1, PT1000 RTD temperature sensor. The parameters are configured on the device via capacitive buttons on the display, or by the timesaving Trafag Sensor Master Android App that utilizes Near Field Communication (NFC). The easy configuration in combination with a comprehensive set of options make the DTP 8180 suitable for a wide range of industrial applications.

See "Product Variations" for alternative product configurations and specifications. Please refer to the Trafag Glossary for guidance. (These items are made to order and have a lead time of 3-4 weeks.)

  • Configuration via NFC with Trafag Sensor Master Android App
  • Display and Electrical Connection rotates independently for proper alignment
  • Analog Output is selectable between mA or VDC
  • Integrated Datalogger
  • Re-scalability from 50 … 100% of the nominal measurement range
Property Value
The information herein is subject to change without notice.
Applications
Hydraulics, Pneumatics, Dynamometers, Test benches, Industrial Automation, Food and Beverage, Process Measurement, Cooling and Lubrication systems, etc.
Measuring principle
PT1000, Class 1, 2 conductors, RTD
Accuracy
±0.5% FS Typ. + Temp Sensor Error
Measurement range
0 ... 30 to 0 ... 7,500 psi
0 ... 2.5 to 0 ... 600 bar
Pressure connections
1/4"NPT Male, 1/2"NPT Male, G1/8" Male, G1/4" Male, G1/2" Male, Tri-Clamp, Sanitary Fitting, others upon request
Electrical Connections
M12x1, 5 Pole and M12x1, 4 Pole
Ambient Temperature -25°C ... +85°C
Shock 50 g / 3 ms
Vibration 10 g (10 ... 2000 Hz)
Protection IP-67 (minimum)
Output signal
4 … 20mA, 0 … 10VDC, 0 … 5VDC, 1 …6 VDC, user configurable
Dielectric strength 100 VAC, 50 Hz
Flyer
PDF Flyer 
Datasheet
PDF Datasheet 
User Manual
PDF User's Manual 
Product Options
Type Code Range Max Over Pressure Burst Pressure NLH Accuracy (BSL) Supply
8180.50.211B.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/4" NPT Male, 50 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.212B.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/4" NPT Male, 100 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.213B.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/4" NPT Male, 150 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.214B.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/4" NPT Male, 200 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.215B.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/4" NPT Male, 250 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.211C.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/2" NPT Male, 50 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.212C.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/2" NPT Male, 100 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.213C.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/2" NPT Male, 150 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.214C.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/2" NPT Male, 200 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote
8180.50.215C.35.PA.P1 -58°F … +302°F ±0.5% FS Typ. + Temp Sensor Error 1/2" NPT Male, 250 mm Probe Length 15 ... 30 VDC 4 … 20 mA, 0 … 10 VDC, and 2 PNP Switchpoints Request Quote