Chat with us, powered by LiveChat Skip to content
***Phytools will be closed 11/28 & 11/29 for Thanksiving .***
***Phytools will be closed 11/28 & 11/29 for Thanksiving .***

Kvaser Memorator Pro 5xHS

SKU #: KV-00778-9

Professional five channel standalone data logger and USB-to-CAN/CAN FD interface with t-Program.

The Memorator Pro 5xHS made by Kvaser is a five channel, high performance CAN bus interface and standalone data logger that allows users to monitor and collect data from up to five CAN channels using a single device. In interface mode the device connects to the PC via USB while in standalone mode it logs data to an SD card. This device supports CAN FD.

The Kvaser Memorator Pro 5xHS offers advanced features such as Message Filtering, Triggers, Error Detection and Generation, Silent Mode, an expandable SD Card slot, Galvanic Isolation, and much more. Configurable using Kvaser's Memorator Config Tool, it is also capable of running user-developed scripts, written in the Kvaser t- programming language. 


  • Monitor 5 CAN channels simultaneously using just one device, or connect the USB cable with a single 9 pin DSUB for single CAN channel monitoring.
  • Supports CAN FD, up to 8 Mbit/s (with proper physical layer).
  • Automatically time synchronises the data transmitted and received across all five buses.
  • Built-in Kvaser MagiSync technology time synchronises with other Kvaser interfaces connected to the same PC, resulting in simpler and more accurate multichannel data capture.
  • Script functionality allows users to develop customised t-script applications written in the Kvaser t programming language.
  • Plug and play installation, and a comprehensive user guide to help make t script development quick and easy.
  • Log data to an expandable SD card slot.
  • LED lights alert user to device status, including signalling a full SD card or card error.
  • Power derived from the USB connection, CAN or an in-built power supply.
  • Compatible with J1939, CANopen, NMEA 2000® and DeviceNet.
Property Value
The information herein is subject to change without notice.
Galvanic Isolation Yes
Bitrate 40-1000 kbit/s
Silent mode Yes
Error frame generation Yes
Error frame detection Yes
Weight 150 grams
Timestamp resolution 2
On board buffer Yes
Maximum message rate, send 20000
Maximum message rate, receive 20000
Sound No
Clock synchronization 1
Dimensions (WxLxH) 23x155x68 mm
Kvaser Memorator Pro 5* HS Datalogger Datasheet
Kvaser Memorator Pro 5xHS Datalogger Datasheet
Specification of Kvaser Memorator Device configuration XML format
Specification of Kvaser Memorator Device configuration XML format
Version V2.1.220215
Kvaser Database Editor Users Guide
Kvaser Database Editor User's Guide
Version V2.0.0
Kvaser t Programming Language
Documentation for the t programming language
Version V4.17.220215
Kvaser SocketCAN Device Drivers
Kvaser SocketCAN Drivers for Linux.
Version V1.10.477
Kvaser Linux Driver and SDK
Linux driver and SDK for Kvaser PCIcan/PCIcanx, Kvaser PCIcanII, Kvaser PC104+, Kvaser PCIcanx II, Kvaser USBcan II, Kvaser Memorator*, Kvaser Leaf family, Kvaser Memorator Pro**, Kvaser USBcan Pro and VirtualCAN. For LAPcan and LAPcan II, you should use version 4.2 of the driver. (*) only with USBcanII functionality, (**) only with USBcan Pro functionality
Version V5.38.841
Kvaser DIADEM Driver
This free driver for National Instrument's DIAdem supports all CAN hardware from Kvaser.
Version V4.1.0
Kvaser Drivers for Windows
Windows drivers for all our CAN hardware. Please check release notes for information on which Windows versions are supported. It also contain a driver for the virtual CAN bus.
Version V5.38.841
Kvaser Firmware Update Tool
Firmware Update tool for most Kvaser devices.
Version V4.27.841
Linux SDK Library
Linux SDK library.
Version V5.38.841
Python module
The Canlib module is a Python wrapper for Kvaser CANlib SDK.
Version V1.20.360
Kvaser LabView VI Library for CAN
Library for National Instrument's LabView. Version for all Kvaser CAN hardware.
Version V19.3.0
Kvaser CANlib SDK
Software development kit - everything you need to develop software for the Kvaser CAN and LIN interfaces. Libraries, header files, sample programs for e.g. C, C++, C#, Visual Basic and Delphi, documentation, and more. Note: you need to download and install the appropriate device drivers separately.
Version V5.38.841
Kvaser Database Editor 3
Kvaser Database Editor 3 (candbfd).
Version V3.17.841
Kvaser Memorator Configuration tool
Configuration tool for Kvaser Memorator Pro 5xHS, Kvaser Memorator 2xHS v2, Kvaser Memorator Light HS v2 and Kvaser Eagle
Version V5.28.841
Kvaser CANKing
A free of charge, general-purpose CAN bus monitor. It works with all CAN interfaces from Kvaser and also with the virtual CAN bus.
Version V6.21.288

Professional five channel standalone data logger and USB-to-CAN/CAN FD interface with t-Program. The Memorator Pro 5xHS made by Kvaser is a five channel, high performance CAN bus interface and stan...