Kvaser Hybrid Pro 2xCAN/LIN

SKU #: KV-01042-0

Kvaser Hybrid Pro 2xCAN/LIN is a flexible, dual channel interface that allows each channel to be assigned independently as classic CAN, CAN FD or LIN. This makes the Kvaser Hybrid Pro 2xCAN/LIN a must-have ’universal interface’ for every engineer involved in automotive communications.

The Kvaser Hybrid Pro 2xCAN/LIN offers advanced features such as support for CAN FD, Silent Mode, Single Shot, Error Frame Generation and Kvaser MagiSync automatic clock synchronization. As a Pro-level device, this interface can host user-developed programs, created using resources provided within Kvaser’s free CANlib SDK. These can be designed to accomplish a range of advanced tasks, such as CAN node simulation and CAN flashing, or create a LIN to CAN gateway. Guidance and code examples are provided.


An essential tool for automotive engineers, CAN and LIN can now be configured using a single tool. Easy access, from climate control to calibration, using one device. This compact, high-performance interface uses a standard USB connector and two high-speed CAN, CAN FD or LIN channels in separate 9-pin D-SUB CAN connectors. Each channel can be configured for either CAN or LIN, allowing multiple configurations tailored to your needs.

  • Hybrid USB CAN/LIN two channel interface with two separate 9-pin D-SUBS
  • t programsallow users to customize the Hybrid Pro 2xCAN/LIN’s behavior
  • Supports CAN FD, up to 5 Mbit/s (with proper physical layer)
  • Supports High-Speed CAN (ISO 11898-2) up to 1Mbit/s and LIN 2.2A (ISO 17987 Part 1-7) up to 20 kbit/s
  • Capable of sending up to 20000 messages per second, per CAN channel, timestamped with a 1 μs accuracy
  • USB-powered (bus V+ reference required for LIN)
  • Kvaser MagiSync – automatic time synchronization between MagiSync-enabled Kvaser interfaces connected to the same PC
  • Single-shot function ensures that failed transmissions will not retry.
  • Error frame generation and error counters
  • LED lights indicate device status
  • Fully compatible with J1939, CANopen, NMEA 2000 and DeviceNet
  • Supplied with Kvaser CANlib and Kvaser LINlib, free software APIs that are common to all Kvaser hardware and enable the channels to be configured intuitively and fast
  • Extended operating temperature range from -40°C to 85°C
Property Value
The information herein is subject to change without notice.
Galvanic Isolation Yes
Bitrate 50-1000 kbit/s (CAN); 1-20 kBit/s (LIN)
Silent mode Yes
Error frame generation Yes
Error frame detection Yes
Weight 170 g
Timestamp resolution 1 μs
Kvaser MagiSync Yes
Maximum message rate, send 20,000
Maximum message rate, receive 20,000
Sound No
Clock synchronization N/A
Dimensions (WxLxH) 50x170x20 mm (body incl. strain relief)
Datashet
Kvaser Hybrid Pro 2xCAN/LIN Datasheet
Kvaser Hybrid Pro 2xCAN/LIN User's Guide
Kvaser Hybrid Pro 2xCAN/LIN User's Guide
Version V2.6.220215
Kvaser t Programming Language
Documentation for the t programming language
Version V4.17.220215
Kvaser SocketCAN Device Drivers
Kvaser SocketCAN Drivers for Linux.
Version V1.10.477
Kvaser Linux Driver and SDK
Linux driver and SDK for Kvaser PCIcan/PCIcanx, Kvaser PCIcanII, Kvaser PC104+, Kvaser PCIcanx II, Kvaser USBcan II, Kvaser Memorator*, Kvaser Leaf family, Kvaser Memorator Pro**, Kvaser USBcan Pro and VirtualCAN. For LAPcan and LAPcan II, you should use version 4.2 of the driver. (*) only with USBcanII functionality, (**) only with USBcan Pro functionality
Version V5.38.841
Kvaser Drivers for Windows
Windows drivers for all our CAN hardware. Please check release notes for information on which Windows versions are supported. It also contain a driver for the virtual CAN bus.
Version V5.38.841
Kvaser Firmware Update Tool
Firmware Update tool for most Kvaser devices.
Version V4.27.841
Kvaser Canlib Android Library
Kvaser CANlib Android Library
Version V1.2.0
Python module
The Canlib module is a Python wrapper for Kvaser CANlib SDK.
Version V1.20.360
Kvaser CANlib SDK
Software development kit - everything you need to develop software for the Kvaser CAN and LIN interfaces. Libraries, header files, sample programs for e.g. C, C++, C#, Visual Basic and Delphi, documentation, and more. Note: you need to download and install the appropriate device drivers separately.
Version V5.38.841
XTM, Free LIN Viewer
A free of charge LIN bus viewer. This demo version only operates in slave mode and only monitors the LIN bus. Works with Kvaser Leaf Professional LIN and Hybrid family of products.
Version V3.8.36
Kvaser CANKing
A free of charge, general-purpose CAN bus monitor. It works with all CAN interfaces from Kvaser and also with the virtual CAN bus.
Version V6.21.288

Kvaser Hybrid Pro 2xCAN/LIN is a flexible, dual channel interface that allows each channel to be assigned independently as classic CAN, CAN FD or LIN. This makes the Kvaser Hybrid Pro 2xCAN/LIN a m...