PCAN USB Adapter

SKU #: IPEH-002021

Shop the PCAN-USB Adapter from PEAK-System Technik to connect any laptop, computer or PC to a CAN bus via USB, facilitating the monitoring and recording of CAN network messages. 

This CAN-USB  interface, with the included CAN monitor software, allows a user to look at CAN network messages, send out CAN data and record bus traffic. (Also available with galvanic isolation of up to 500V between the CAN signals and the host-PC.)

The CAN bus signals are routed to a 9-pin SUB-D plug and an integrated LED shows the operating state of the PCAN-USB Adapter.

The IPEH-002021 PCAN-USB package includes device drivers for Windows® 11 (64-bit) and 10 (32/64-bit), the PCAN-Basic API, and the PCAN-View CAN monitor software. Linux drivers are also available. For customers needing more sophisticated CAN Analyzing software we have PCAN-Explorer 6.


  • Interface in compact plastic casing
  • CAN transfer rates up to 1 Mbit/s
  • Compliant with CAN specifications 2.0A (11-bit ID) and 2.0B (29-bit ID)
  • CAN bus connection via D-Sub, 9-pin (to CiA® 102)
  • NXP SJA1000 CAN controller, 16 MHz clock frequency
  • NXP PCA82C251 CAN transceiver
  • Hardware can be reset via software
  • 5-Volts supply to the CAN connection can be connected through a solder jumper, e.g. for external transceiver
  • Voltage supply through USB bus
  • USB connection (USB 1.1, compatible with USB 2.0 and USB 3.0)
  • Optional galvanic isolation on the CAN connection up to 500 V (see IPEH-002022)
Power Consumption 1 Channel max. 200mA
Baud Rate CAN: max. 1 MBit/s
Pinout C.I.A. DS-102 (CAN_H = 7, CAN_L = 2, CAN_GND = 3)
Transceiver CAN: NXP / Philips PCA82C251
Dimensions 75 x 43 x 22 mm
Weight 78 g
Software Driver: Windows® 11 (x64) and 10 (x86/x64)and Linux
Tools: PCAN-View for Windows®
Controller(s) CAN: NXP / Phillips SJA1000
Connector(s) PC: USB plug type A, USB Full-speed mode, compatible to USB 1.1, 2.0 and USB 3.0
CAN: ISO 11898-2, complies with CiA-recommendation DS 102
I/O & IRQ automatically assigned via "plug n play"
Specification CAN: 2.0A (Standard format) and 2.0B (extended format)
Operating temperature -40°C to +85°C
Storage Temperature -40°C to +100°C
Relative humidity 15% to 90% (non-condensing)
Enclosure IP20, Plastic Enclosure
EMC Directive EN 55024:2003-10
EN 55022:2007-04
EC directive 2004/108/EG
Certifications CE, RoHS
PCAN-USB Manual
PDF User's Manual in English
Device driver setup for Windows
Installation package from PEAK-System for device drivers and tools for Windows ® 11 (x64) and 10 (x86/x64) for our PC interfaces. Tools included: PEAK-CPL, PCAN-View, PLIN-View Pro and Virtual PCAN-Gateway.
Device drivers for Linux
Device driver for PEAK CAN interfaces from Kernel 2.6.
PCAN-USB firmware
Firmware upgrade
PCAN-View
Software for displaying, sending and recording CAN and CAN FD messages for Windows ® 11 (x64) and 10 (x86/x64).
PCAN-Basic API
API for developing applications with CAN and CAN FD connections for Windows ® 11 (x64) and 10 (x86/x64).
PCAN-Basic API (Linux)
API for developing applications with CAN connection for Linux.
PCAN-CCP API
API for developing software for communication with control units according to the CAN Calibration Protocol (CCP) for Windows ® 11 (x64) and 10 (x86/x64).
PCAN-XCP API
API for developing software for communication with ECUs in accordance with the Universal Measurement and Calibration Protocol (XCP) for Windows ® 11 (x64) and 10 (x86/x64).
PCAN-ISO-TP API
API for the transmission of data packets according to ISO-TP (ISO 15765-2) for Windows ® 11 (x64) and 10 (x86/x64).
PCAN-UDS API
API for communication with control units according to UDS (ISO 14229-1) for Windows ® 11 (x64) and 10 (x86/x64).
PCAN-OBD-2 API
API for vehicle diagnosis according to OBD-2 (ISO 15765-4) for Windows ® 11 (x64) and 10 (x86/x64).
PCAN-PassThru API
Pass-Thru API and connection of Pass-Thru software to PEAK-CAN interfaces. Installation for Windows ® 11 (x64) and 10 (x86/x64) including interface DLLs, configuration software, PCAN-Basic API and PCAN-ISO-TP API. Documentation included in the download.
Bit Rate Calculation Tool (Windows Version)
Software for calculating register values ​​for CAN and CAN FD bit rates for Android, iOS and Windows ® 11 (x64) and 10 (x86/x64).
Bit Rate Calculation Tool (Android Version)
Software for calculating register values ​​for CAN and CAN FD bit rates for Android, iOS and Windows ® 11 (x64) and 10 (x86/x64).
Bit Rate Calculation Tool (iOS Version)
Software for calculating register values ​​for CAN and CAN FD bit rates for Android, iOS and Windows ® 11 (x64) and 10 (x86/x64).
Windows CE6 package
PCAN-CE package for Microsoft Windows ® CE 6.x.
Windows 2000 package
Windows ® 2000 device driver including CAN monitor PCAN-View.

Fast & Free Shipping With Phytools

Experience unparalleled customer service with Phytools. Shop hardware and software solutions with complete peace of mind with our 30-day money back guarantee.

Why Phytools?

  • Official North American distributor for products from PEAK-System Technik, SYS TEC electronic, and GEMAC
  • Authorized distributor for products from KUNBUS, Kvaser, MACH Systems, and Embedded Systems Academy
  • Member of CAN in Automation (CiA) and EtherCAT Technology Group (ETG)
  • Over 20 years of experience
  • Diverse customer base across industries such as automotive, industrial automation, medical equipment, aerospace, agriculture, construction, and renewable energy
  • Offers a large selection of industrial networking solutions
  • In-house expertise to provide efficient and cost-effective products
  • Provides support from pre-sales to rapid resolution of issues to exceed customer expectations.

FAQs

What is the galvanic isolation for the PCAN-USB adapter?

The opto-decoupled version guarantees galvanic isolation of up to 500 Volts between the PC and the CAN side. Choose the galvanically isolated version if there are HV power lines near the communication bus lines. Galvanic isolation protects the PC from any high voltage disturbances on the CAN signal lines which can damage the adapter and/or the USB port on the host PC. 

What do I do if I am unable to connect my PCAN USB device to my CAN network?

Make sure you have downloaded all the necessary drivers and other software packages from the “downloads” tab on the product page.

Is there more advanced CAN analyzing software available?

Yes, for more sophisticated CAN analyzing needs, the PCAN-Explorer 6 software is available.

Shop the PCAN-USB Adapter from PEAK-System Technik to connect any laptop, computer or PC to a CAN bus via USB, facilitating the monitoring and recording of CAN network messages.  This CAN-USB  inte...